Skip to main content

Table 1 Results of Dialux simulations for three of the different scenarios which were analyzed: a cellular office, a health care bedroom and a train coach

From: Design and prototyping of a family of OLED luminaires for indoor environmental applications: results from the ODALINE project

Cellular office (15 m2)

Lighting system

# of OLEDs/ luminaire

# of luminaires

Total areaa [cm2]

hm [m]

LPD [W/m2]

Visual task area

Room areab

Em [lux]

U [−]

Em [lux]

U [−]

 Ambient lighting (downlight suspended luminaires)

  OLED Philips

21

3

9.765

2.2

29.3

512

0.75

421

0.47

  OLED LGChem

40

3

12.000

2.2

11.2

508

0.76

460

0.44

  Light Field LED Zumtobelc

/

2

7.688

2.2

5.9

500

0.57

553

0.27

 Ambient lighting (downlight suspended luminaires) + downlight free standing luminaire for the work plane

  OLED Philips

16 (susp.)

3 + 1

3.875

2.2 (susp.)

26.5

531 (piant.183)

0.58

386

0.49

+9 (stand)

1.7 (stand)

  OLED LGChem

16 (susp.)

3 + 1

9.600

2.2 (susp.)

8.95

510 (piant.175)

0.63

391

0.4

+9 (stand)

1.7 (stand)

 Free standing luminaire for the work plane (downlight OLED/uplight LED)

  OLED Philips

 

20 OLED

3100 (OLED)

1.7

13.3

488

0.35

232

0.28

  OLED LGChem

 

25 OLED

 

1.7

5.5

352

0.37

173

0.34

Hospital bedroom (patients’ room)

 Bedhead with downlight luminaires

  OLED Philips

6

1

930

1.5

1.7

191

0.7

  

  OLED LGChem

6

1

600

1.5

0.7

103

0.7

  

 Bedhead with downlight OLED/uplight LED luminaires

  OLED Philips

6

2

 

1.5 OLED

7.25

540

0.9

  

1.7 LED

  OLED LGChem

6

2

 

1.5 OLED

6

453

0.9

  

1.7 LED

  BELIA Zumtobel (LED)d

/

1

2.726 (tot)

1.5 OLED

6

401

0.9

  

1.7 FLUO

Train coach

 Ambient lighting of a modular bay (4 facing seats + corridor)

  OLED Philips

19

/

2.945

2

19 ca

388

0.7

306

0.47

  OLED LGChem

19

/

1.900

2

3.8

197

0.66

64

0.06

  1. h m mounting height [m], LDP Lighting Power Density [W/m2]
  2. atotal luminous area for a single luminaire
  3. broom area minus a peripheral stripe having a depth of 50 cm
  4. cfor comparative purposes, a simulation with a suspended downlight luminaire by Zumtobel, equipped with LEDs was also performed
  5. dfor comparative purposes, a simulation with a downlight/uplight bedhead by Zumtobel, equipped with 2 54 W fluorescent tubes, was also performed