Table 3 Differences of radiant flux (ΔΦ e ), luminous flux (ΔΦ v ), correlated color temperature (ΔCCT), chromaticity (Δu’v’) and general color rendering index (Δ R a ) between the simulated and the measured spectral emission curves for the four phosphor mixtures

From: Measuring, simulating and optimizing current LED phosphor systems to enhance the visual quality of lighting

G1/R1

CCT/K

Δ Φv/lm

CRI, Ra,meas

Δ CRI Ra

Δ CCT/K

Δ u'v'wtq

Δ u'v'm

Δ u'v's

Δ Φe/%

Δ Φe/W

2700

2

78

4

238

1.39E-02

7.31E-04

1.02E-02

0.4

0.0083

4300

1

82

7

182

1.09E-02

4.12E-04

8.90E-03

3.6

0.0094

5600

1

83

1

519

7.78E-03

3.43E-03

8.44E-03

3.6

0.0058

6200

0.1

84

1

260

4.30E-03

4.72E-03

3.13E-03

0.5

0.0044

8700

0.9

81

3

1523

1.23E-02

2.91E-03

1.23E-02

4.3

0.0074

G1/R2

CCT/K

Δ Φ v /lm

CRI, R a,meas

Δ CRI Ra

Δ CCT/K

Δ u'v' wtq

Δ u'v' m

Δ u'v' s

Δ Φ e /%

Δ Φ e /W

2700

4

62

1

257

1.43E-02

1.33E-03

1.08E-02

12.2

0.0102

3000

2

67

0

208

8.03E-03

1.46E-03

4.51E-03

6.4

0.0058

4000

1

71

1

175

4.55E-03

8.85E-04

2.22E-03

2.1

0.0055

5000

1.9

73

3

198

6.55E-03

3.85E-03

9.01E-05

3.7

0.0069

7900

0.9

76

1

536

4.49E-03

2.34E-03

3.48E-03

3.1

0.0052

G2/R1

CCT/K

Δ Φv/lm

CRI, R a,meas

Δ CRI Ra

Δ CCT/K

Δ u'v'wtq

Δ u'v'm

Δ u'v's

Δ Φe/%

Δ Φe/W

2700

0

82

2

50

2.18E-03

1.72E-03

2.29E-03

2.5

0.0052

3100

0

85

1

71

3.72E-03

1.15E-03

6.55E-04

2.2

0.0040

4300

1

85

2

23

2.92E-03

5.86E-04

3.66E-03

1.9

0.0063

4700

0.0

85

4

175

1.02E-02

4.91E-04

8.75E-03

3.9

0.0053

5200

0.4

85

3

7

2.26E-03

4.98E-03

7.28E-03

2.8

0.0050

6100

1.0

82

3

295

9.84E-03

3.41E-03

4.04E-03

0.0

0.0051

8000

0.2

81

1

329

3.63E-03

2.89E-03

1.35E-03

2.5

0.0053

G2/R2

CCT/K

Δ Φv/lm

CRI, R a,meas

Δ CRI Ra

Δ CCT/K

Δ u'v'wtq

Δ u'v'm

Δ u'v' s

Δ Φ e /%

Δ Φ e /W

2700

0

63

1

91

6.64E-03

9.84E-04

5.18E-03

3.6

0.0077

3000

0

66

2

293

1.29E-02

1.25E-03

1.16E-02

4.7

0.0101

4000

0

72

4

67

6.01E-03

1.14E-03

5.26E-03

3.4

0.0061

4900

1.3

74

4

169

3.33E-03

3.35E-04

3.51E-04

5.9

0.0111

6800

0.3

76

7

35

6.21E-03

3.82E-03

2.23E-03

2.5

0.0097

7500

0.0

76

7

243

7.37E-03

3.72E-03

2.50E-03

4.0

0.0122

  1. Δu'v'ms: distance between the chromaticity points of the measured and simulated PC-LEDs; Δu'v'wtq,m: distance between the chromaticity point of a measured PC-LED spectrum and its reference light source (the measure of visual white tone quality for the measured PC-LED spectrum); Δu'v'wtq,s: the same for the corresponding simulated spectrum; Ra,m is the CIE general color rendering index computed from the measured spectrum (E-02 means · 10-2, etc.).